Fire Dampers


Fire dampers prevent fire and smoke from spreading

A building is divided into fire and smoke compartments in order to restrict the space and time dependent spread of fire and smoke during a fire. To achieve this goal, the spread of fire and smoke from the affected fire compartment to other compartments must be prevented. Walls and ceilings that separate fire compartments from each other must therefore have the necessary fire resistance.

Many modern buildings are equipped with air conditioning systems. The ventilation ducting of these systems penetrate walls and ceilings and makes the building vulnerable as far as the required fire resistance rating is concerned. Without further measures, fire protection would no longer be guaranteed. Fire dampers ensure, however, that ventilation ducting is isolated when a fire occurs.

Types FK-K90

  • Rectangular fire damper
  • General building inspectorate licence
    Z-41.3-321
  • Reduced differential pressure and sound power level
  • Dry mortarless installation with installation kit
  • Remote controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

more details

square, rectangular

W: 200 – 1,500 mm
H: 200 – 800 mm
Intermediate sizes in 1-mm increments
Fire resistance class:
K90 acc. to DIN 4102

Type FKS-EU

  • Rectangular fire damper
  • General building inspectorate licence
    Z-41.3-653
  • Reduced differential pressure and sound power level
  • Dry mortarless installation with installation block
  • Mortar based installation with a perimeter mortar infill, also in lightweight partition walls
  • Remotely controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

more details

square, rectangular

W: 200 – 800 mm, intermed. sizes in 50-mm increments
H: 100 – 200 mm
Fire resistance class:
K90 acc. to DIN 4102

Type FKRS-EU

FKRS-EU mit Schmelzlot
  • Circular fire damper
  • General building inspectorate licence
    Z-41.3-688
  • Reduced differential pressure and sound power level
  • Dry mortarless installation with installation block
  • Mortar based installation with a perimeter mortar infill, also in lightweight partition and shaft walls
  • Remotely controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

more details

circular

Ø 100 – 315 mm
Classification:
EI 90 (ve, ho i ↔ o) S
acc. to EN 13501-3
Fire restistance class:
K90 acc. to DIN 4102

Types FKR-01-K90 · FKR-02-K90

  • Circular fire damper
  • General building inspectorate licence
    Z-41.3-322
  • Reduced differential pressure and sound power level
  • Mortar based installation with a perimeter mortar infill
  • Remotely controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

more details

circular

Ø 200 – 710 mm
Fire resistance class:
K90 acc. to DIN 4102

Types FV-K90 · FVZ-K30

  • Circular fire protection valve
  • General building inspectorate licence
    Z-41.3-317
  • Reduced differential pressure and sound power level
  • Dry mortarless installation with installation kit
  • Mortar based installation with a perimeter mortar infill, also in lightweight partition walls
  • Integration into the centralised BMS with TROXNETCOM

more details

circular

Ø 100 – 200 mm
Fire resistance class:
Depends on usage
or K30U

FK-K90 for air transfer application

  • Rectangular fire damper FK-K90 with spring return actuator, smoke detector RM-O-3-D and cover grilles on both sides
  • General building inspectorate licence
    Z-6.50-2031
  • Integration into the centralised BMS with TROXNETCOM

more details

square, rectangular

W: 200 – 1,500 mm
H: 200 – 800 mm
Fire resistance class:
K90 nachgewiesen durch
Zulassung Z-41.3-321

Type KU-K30

  • Rectangular fire damper in conjunction with air terminal devices
  • General building inspectorate licence
    Z-41.3.320
  • Reduced differential pressure and sound power level
  • Installation in stand-alone fire-resistant suspended F30 ceilings
  • Design with 24 V or 230 V spring return actuator
  • Control by means of smoke detectors or central fire alarm systems
  • Integration into the centralised BMS with TROXNETCOM

more details

square

 300 – 625 mm
Fire resistance class:
K30-U acc. to DIN 4102

Type E01-K90

  • Rectangular fire damper
  • General building inspectorate licence
    Z-41.3-323
  • Reduced differential pressure and sound power level
  • Remotely controlled with spring return actuator
  • Integration into the centralised BMS with TROXNETCOM

more details

square, rectangular

W: Approx. 300 – 1,500 mm
H: Approx. 300 – 800 mm
Fire resistance class:
K90 acc. to DIN 4102

Installation examples

Built-in, reliable safety
More installation examples