CONSTANTFLOW


Regulators and limiters for supply or exhaust air of constant volume flow systems

Constant volume flow regulators facilitate commissioning in constant systems (CVS). The desired air flow is set at an external scale (RN/EN). There is no other complex or time-consuming calibration.

Even air distribution among the multiple air diffusers only occurs with the appropriate duct layout or after adjustment of the throttle dampers. Volume flow limiters for sliding into the air duct at each diffuser make sense, since both commissioning is easier and quicker and exceeding of the design criteria is prevented.

Type VFC

VFC
  • Circular volume flow controller for low velocities
  • Suitable for constant and variable volume flow systems
  • Selection according to nominal size of the duct system
  • Commissioning in one step
  • Flow rate adjustment without special tools
  • Retrofit of actuator easily possible


more details

circular

6 – 370 l/s
20 – 1,332 m³/h
13 – 784 cfm
Δp: 30 – 500 Pa

Ø 80 – 250 mm

Casing air leakage flow rate complies with DIN EN 1751, class A

Type VFL

VFL
  • Mechanical system-powered volume flow limiter
  • High control accuracy of ± 10 %, relative to Vnominal
  • Easy installation into round air ducting
  • Can be installed in any orientation

more details

circular

4 – 250 l/s
15 – 900 m³/h
8 – 530 cfm
Δp: 30 – 300 Pa

Ø 80 – 250 mm

Type RNS

RNS 125
  • Circular mechanical automatic controller for low false ceilings
  • Factory functional testing of each unit
  • No on-site calibration required
  • Units are essentially ready for commissioning after installation

more details

circular

11 – 140 l/s
40 – 504 m³/h
23 – 297 cfm
Δp: 50 – 1,000 Pa

Ø 80 – 125 mm

Casing air leakage flow rate complies with DIN EN 1751, class A

Type RN

RN
  • Circular mechanical automatic controller
  • Factory functional testing of each unit
  • No on-site calibration required
  • Units are essentially ready for commissioning after installation

more details

circular

11 – 1,400 l/s
40 – 5,040 m³/h
23 – 2,966 cfm
Δp: 50 – 1,000 Pa

Ø 80 – 400 mm

Casing air leakage flow rate complies with DIN EN 1751, class A

Type EN

EN
  • Rectangular mechanical automatic controller
  • Factory functional testing of each unit
  • No on-site calibration required
  • Units are essentially ready for commissioning after installation

more details

square, rectangular

40 – 3,360 l/s
144 – 12,096 m³/h
85 – 7,120 cfm
Δp: 50 – 1,000 Pa

W: 200 – 600 mm
H: 100 – 600 mm

Type WT · WL · EL

WT
  • Air Heater
  • Hot water for types TVZ, TVR, TVJ, TVT, RN and EN
  • Electric for types TVR and RN
  • Installation, heating output control and the supply connections are provided by customer

more details

circular, square, rectangular

10 – 10.100 l/s
36 – 36.360 m³/h
21 – 21.401 cfm

Ø 100 – 400 mm
B: 200 – 1.000 mm
H: 100 – 1.000 mm

Q: 0,25 – 116 kW